Rayence XR5

  • 40kW generator with 200 kHU X-ray tube and manual collimator
  • Full Console APR to X-ray generator integration with two-way communication
  • 4-wayfloating tabletop (550 lb. weight capacity; 32 x 90 in. tabletop dimensions)
  • One-yearX-ray system warranty (Three-year wireless detector warranty)
  • The XR5 is compatible with all Rayence detectors and advanced Xmaru Image Acquisition software.

Description

Enhance both staff workflow and the patient experience with auto tracking of the vertical wall stand and table Bucky detector movements. Requiring no special ceiling orelectrical preparation, the XR5 can be installed in rooms with dimensions ofjust 13 feet wide by 13 feet deep by 8 feet high and 208-240VAC line voltage.

 

  • 40kW generator with 200 kHU X-ray tube and manual collimator
  • Full Console APR to X-ray generator integration with two-way communication
  • 4-wayfloating tabletop (550 lb. weight capacity; 32 x 90 in. tabletop dimensions)
  • 16in. minimum floor-to-focus height (58 in. total tube head travel)
  • Rayence14x17 Cesium Iodide wireless detector and Xmaru image acquisition software
  • One-yearX-ray system warranty (Three-year wireless detector warranty)
  • The XR5 is compatible with all Rayence detectors and advanced Xmaru Image Acquisition software.

 

 

Additional information

Generator

Output 40kW

kV Range 40-125kV

mA Range 10-500mA

Input Phase / Voltage 1Ф / 208-2300Vac

Exposure Time Range 6.3s Max.

Tube

Focal Spot Value 0.6 – 1.5 mm

Target Angle 16°

Target Diameter 74mm

Anode Heat Content 200 kHU

Cooling Method Natural / Forced Air

Collimator

Type Manual

Power Output DC 24V

Projection Lamp 150W Halogen Lamp

Lamp Timer Push Button, 30 seconds

Rotation Angle -10 ˚ ~ 180 ˚ as minimum

APR Memory No

Laser Guide No

Max. Window 18.9 x 18.9 in (SID 40 in)

Min. Window Time 2 x 2 in (SID 40 in)

Floor Mounted Power Required

24V, 3A

Tube Stand

Tube Stand 1,940 mm

SID Range 40 in ~ 72 in

Vertical Travel 58 in

Longitudinal Travel 100 in

Tube Rotation Range -135˚ ~ +135˚

Tube Arm IN / OUT 4.7 in

4 Way Table

Dimensions 90 in (l) x 32 in (w) x 26 in (h)

Forward-Backward Movement ± 4.2 in

Left-Right Movement ± 11.2 in

Table Cabinet Movement ± 347mm (±10)

Load Capacity 550 lbs.

6 Way Table

Load Capacity 660 lbs.

Max lift capacity 550 lbs.

Contact

California Radiographics Inc.

3335 Soquel Dr, Soquel, CA 95073
(831) 462-8399

About Us:

California Radiographics has provided the hospital, medical clinic and private practice community with diagnostic imaging products and services since 1977.

Environments/Specialties

Hospitals/Clinics
Urgent Care
Imaging Center
Women’s Health
Orthopedic
Podiatry
Chiropractic
Veterinarians